Recent Changes - Search:

edit SideBar

Trigger modes

Triggering can be done in frequency domain (e.g. scanning a certain span) or in time domain (e.g. with zero span). Triggering in frequency domain can be slow due to the time required to scan the frequency span.

  • AUTO is the normal spectrum analyzer scanning mode, triggering is not active.
  • NORMAL will display a new scan as soon as a signal in the scan causes a trigger event.
  • SINGLE will wait for a signal to cause a trigger event and display the scan. Restart the waiting for an event by activating SINGLE again.
  • LEVEL activates a keypad for entering the trigger level. The specified trigger level will be shown in the status panel and as a blue line
  • EDGE toggles the trigger edge direction: UP (level crosses from below to above) or DOWN (level crosses from above to below)
  • TRIGGER toggles the trigger position on the screen: PRE, MID or POST. When using MID or POST trigger you can capture and display the signal before the trigger event happened
  • INTERVAL sets the time grid interval for starting a scan. Set to zero to deactivate. Useful for fixed-interval repetitive events.
  • BACK returns to the Level menu

The active trigger level is shown on the screen as a blue line and in the status at the left. The trigger level in the status is shown in red when waiting for the trigger to happen and in green when a single trigger happened

Edit - History - Print - Recent Changes - Search
Page last modified on March 29, 2026, at 06:43 AM